vicorpower.com Rev 1.0 Cool-Power
®
800 735.6200 11/2012 Page 3 of 4
Programming Synchronization Delay
The PI33XX-2X provides an I
2
C
TM
Standard Mode
digital interface that enables the user to
program phase delays. This is a one-time
programmable option to the device. To set a
delay, the user needs to assign a unique Device
Address (see Table 2) to wake up the device
during programming. Then send the
synchronization delay address (21h) and the
delay data (OEh) while adhering to I
2
C protocols
and Figure 4 sequencing.
The following figure demonstrates the proper
steps to program a single phase-delay. The
device address is determined by the user and
the synchronization delay is provided in Table 1.
The device address is represented as XXh (Bold)
in Figure 6. Because this process in not
reversible, it is important to follow all steps in
Figure 4.
1) Clear all Registers to 00h with the device enabled
2) Enter Test Mode 5
3) Disable then Re-enable the Device (Enable Pin)
4) Set Desired Delay
5) Disable Device (Enable Pin)
6) Return to Test Mode 0
7) Repeat 1); Clearing all Registers
8) Enable Device (Enable Pin); Programming is Complete
Figure 4 - Showing the 8 Steps Required to Program a Single 1/3 Phase Delay
Comentarios a estos manuales