8 9
Suggested Wire Gauge
Function Wire Gauge Application
DC Input/Output Leads #20 0 A - 3 A
#18 4 A - 6A (PlugMate)
#16 7 A - 10 A
#14 11 A - 15 A
#12 16 A - 25 A
#10 26 A - 40 A
#8 41 A - 65 A
#6 66 A - 104 A
#4 105 A - 160 A
PlugMate Output Connectors General Information
Vicor P/N 25073
Vicor P/N 25067
Vicor P/N 25061
PlugMate
(Factory Installed Option)
Micro PlugMate
Mini PlugMate
Maxi PlugMate
P
in # Function Pin # Function
1 +Vout 5 +Vout
2
+Vout 6 N/C
3
–Vout 7 SC
4
–Vout 8 –Vout
Pin # Function Pin # Function
1 +Vout 10 +Vout
2 +Vout 11 +Vout
3 +Vout 12 +Vout
4 N/C 13 +S
5 N/C 14 SC
6 N/C 15 –S
7 –Vout 16 –Vout
8 –Vout 17 –Vout
9 –Vout 18 –Vout
Pin # Function Pin # Function
1 +Vout 13 +Vout
2 +Vout 14 +Vout
3 +Vout 15 +Vout
4 +Vout 16 +Vout
5 +Vout 17 +Vout
6 N/C 18 +S
7 SC 19 –S
8 –Vout 20 –Vout
9 –Vout 21 –Vout
10 –Vout 22 –Vout
11 –Vout 23 –Vout
12 –Vout 24 –Vout
Mating Connector Amp. P/N Vicor P/N
Housing TYC-794657-8 25056
Pin 1-106529-2 24796
Kit 25073
Mating Connector Amp. P/N Vicor P/N
Housing TYC1-794657-8 25050
Pin 1-106529-2 24796
Kit 25067
Mating Connector Amp. P/N Vicor P/N
Housing TYC2-794657-4 25044
Pin 1-106529-2 24796
Kit 25061
Please Note:
VIPACs that contain multiple modules configured as a single output
(paralleled for power or redundancy) MUST have their Outputs and
Sense connected to each other at the load.
Trimming
Provisions have been made on PlugMate output connectors for adding
resistors to trim the output voltage up or down. Consult the design
calculator, for Rd/Ru trim resistor values, located at vicorpower.com.
Rd = Trim Down
Ru = Trim Up
DO NOT OPERATE A PARALLEL CONFIGURATION WITH ONLY ONE MODULE CONNECTED.
Additionally one module must be designated as “Master” by having all other modules configured
as “Boosters”. Boosters are created by shorting the SC pin to –S.